HMI AC Changelog ================ 1.3.1.37524 *** Match with firmware 1.3.1.37523 or later - Fixed display problem for EOH Shell 2 - Fixed Timeline in LMF Twin shell furnaces - Fixed text when deleting a PowerProgram Step - Fixed CPU changed disclaimer in non-english language translations - Fixed potential PowerProgram model problem by forcing a model upgrade 1.3.1.37383 *** Match with firmware 1.3.1.37408 or later - Added Japanese user manual and updated resources - Added publication "Vibration Electrode Will Raise" to RegExtended bitmap - Added ability to set “Taps Changed Counter” from Electrical System screen - Added different fixed values for Error (X Axis) in R/Z Graph and I Graph - Changed Shaper speed scaling based on the units selected in Furnace Type - Changed CPU Changed Disclaimer to let the user select the active web server IP - Improved vibration alarm display to better visualize configurated Smart Arc logic - Increased the default Disk Space usage for logs from 40 GB to 100 GB - Fixed null validation for variables used in Event Log charts - Fixed Import Configuration from webserver and added the option to bring Config.tgz from a running Webserver. - Fixed Logs Disk Quota now determines allowed disk space correctly before doing any clean up - Fixed Special Variables Data Grid creation from xml - Fixed Shaper scale text and value for Speed chart - Fixed wrong data source path for Air In Hydraulic Alarm led - Fixed OutOfMemoryException that happened trying to access a destroyed control graphics object 1.3.1.36885 *** Match with firmware 1.3.1.36614 or later - Increased maximum size for upgrade files - Improved Phase Balance database performance - Updated Russian Language resources - Updated Swedish Language resources 1.3.1.36706 *** Match with firmware 1.3.1.36614 or later - Updated HMI Manual English - Added Vibration WindowOn% and Filtered Z & Y to Output map - Added min Z RMS parameter to vibration alarm model - Added CPU type reporting in HMI's title - Added validation to avoid executing requests from old web servers - Added scroll to Event Color List in General Settings (Heat Events Color Display) - Added callback for restoring VMEIO channel displays - Updated Vibration Alarm labels - Updated Swedish Language (Work in progress) - Updated Russian Language - Updated EventLogs table titles to fit larger text in Russian - Fixed EventLogs problem when using a Heat Prefix (Work in progress) - Fixed Furnace Shell Top View in Furnace Type to work on several resolutions - Fixed Size of LogOnDialog to fit larger text - Fixed units in Furnace Type: Electrode Mechanical System according to language - Fixed color of Center Frequency Buttons in IOFilters screen when saved - Fixed issue when trying to reset accumulator values - Fixed Regulator Out Offset - Fixed frequent HMI logout in Performance Heat Report charts 1.3.1.35726 *** Match with firmware 1.3.1.35557 or later - Fixed Integral Reset feature in External Loop screen 1.3.1.35564 *** Match with firmware 1.3.1.35557 or later - Added Russian Language support (under revision) - Added VibAvgZThreshold variable scaling - Fixed HeatID displays for numbers with more than 8 digits 1.3.1.35432 *** Match with firmware 1.3.1.35523 or later - Added alarm ArcingRiskHighVoltage - Added DataHandling variables HeatAvgMW & ChargeAvgMW - Improved Vibration alarm raise logic to use SmartARC enable and NumberOfHeats - Increased HeatID limits in Heat Sheet Report (64bit) - Added HMI support for HeatIDs up to 15 digits (16 will not work) - Fixed validation on Detach button in PerformanceHeatSheet, "unable to detach graph" message added. 1.3.1.35010 *** Match with firmware 1.3.1.34908 or later - Fixed issue that affected use of Heat's AvgMW variable in charts 1.3.1.34874 *** Match with firmware 1.3.1.34908 or later - Added Clamp variables: ClampOpenCount, ClampOpenTime, PowerOffInnerLongestClamp, PowerOffInnerLongestClampAny - Improved System Upgrade, now validates proper file version (AC vs DC) - Updated AMI icon for dialogs - Fixed HMI cosmetic issues (English, Spanish and French) - Fixed location of some controls in Power Curves - Fixed problem in Heat Timeline and export chart when report spans two years 1.3.1.34442 *** Match with firmware 1.3.1.34435 or later - Fixed VME I/O units/decimals scaling, moved to firmware 1.3.1.33597-Pohang - Added a Timeline button to Heat Chart - Fixed LMF Overview, Arc Length was not being displayed correctly in PLC mode - Fixed issue in CaveIn screen (path not found) - Fixed some code in preparation for translations - Fixed problem when exporting data files that could crash the HMI 1.3.1.33340 - Fixed a problem when exporting data files - Fixed a problem with the Phase Balace screen - Fixed a problem when loading a pencil and shown other ChartType - Fixed Special Variables grid color to black 1.3.1.33023 - Added new PrimaryFrameExt output object - Reverted to hide the events by default, user needs to Show Events to see them - Changed some strings to resources that were not being translated - Fixed problem in Phase Balance not showing data since RWIeu introduction - Fixed some labels that could be shown in the windows language (instead of language in User Preferences) 1.3.1.32711 - Fixed problem loading Pencil sets (introduced in 1.3.1.32462). It caused unhandled exceptions in several charts and problems loading custom pencil sets 1.3.1.32462 - Added French translation - Added Secondary energy variables block (MWh, MVARh, MVAh) - Changed charts, show the events by default, user can Hide Events - Changed charts, keep the selected events when navigating - Changed current range (0-655.35 kA) - Fixed LMF Overview to show the shadow mode - Fixed Performance Heat Sheet to validate - Fixed IndexOutOfRange exception spam when StoredRegulatorId file is empty - Fixed Power Program exception showing "Path not found, seeking ChargeX" - Fixed VarsConfig PF limits to 0.01 to 1 - Fixed alarm messages that had no spaces - Fixed IOConfiguration screen incorrect modified status - Fixed Phase Balance data storage 1.3.1.31784 - Added support for adjusting Counterbalance hydraulic systems - Added Overview bar variables for Electrode Pressure, Position, Speed and Valve Spool% - Added phase information to alarm messagese - Updated company name references in HMI and UsersManager - Changed Integral defaults to slower values - Changed Data Export variable order, the new RWIeu columns are moved to the right - Changed Shaper model defaults for Idecoupling (Bowman, Krueger. Arc Furnace Physics) - Fixed Timeline Statistics heat inclusion logic that could calculate incorrect statistics - Fixed Timeline heat count, it wasn't reset when selecting a day without heats - Fixed incorrect "Heat report not found" when navigating heats - Fixed Electrode Gain Test errors when switching shaper profiles - Fixed HMI offline error that could show an old configuration file 1.3.1.31195 - Fixed a visual bug that affected Data Handling trends, the initial load of RWIeu from the server was clipped incorrectly 1.3.1.31192 - Fixed a big visual bug that mishandled negative data. Most numeric displays and bar charts were affected 1.3.1.31089 - Added RWIeu, VLL, ArcVoltage and Y to overview bar variables - Fixed web server bug that prevented Phase Balance data from being processed - Updated default Vars Config min/max/span - Updated handling of RWIeu to support range of 0-655 kW V/cm^2 1.3.1.30954 - Added RWIeu and fixed RWI calculation and units (reported RWI and ArcLength values will be slightly higher now) - Application icon was changed, company name and logo were updated - Added heat report units for RWI and I2h - Updated labels on ElectricalSystem screen on tabs Furnace, Reactor, Substation and Short Circuit (e.g. "%Z MVAref" is now "MVA for %Z") - Fixed timeline duration conversion in locales with comma as decimal separator - Improved concurrency for PhaseBalance database and screen that was causing errors with database locks - Fixed heat report counters that overflowed at 32767 - Fixed documentation for Dynamic NCC Setpoint Phase 1 scaling 1.3.1.30769 - Fixed Heat report values when running in locales with comma as decimal separator and point as thousands separator (e.g. Aperam Chatelet) - Fixed keyboard problem with shift key that got stuck once pressed 1.3.1.30543 - Fixed Electrode speed test chart display bug. Versions 30211, 30445 and 30534 have several problems in this screen. 1.3.1.30534 - Fixed Electrode speed test phase 3 bug 1.3.1.30445 - Fixed HMI Events Error Message - Fixed HMI Events number not match - Fixed virtual keyboard problem (Shift 7) - Reverted temporary fix for wrong HMI time issue in Concurrent CPUs (fixed in firmware 1.3.1.30411) 1.3.1.30211 - Temporary fix for the wrong HMI time issue in Concurrent CPUs 1.3.1.29829 - Added NetworkExceptions.txt configuration file to Win.Proxy Service to be able to ban or allow IP subnets from forwarding traffic to the PX3, default is to allow forwarding of all traffic - Added HmiHideOnShadow to the GeneralSettings screen - Fixed I/O map documentation - Added Nexus 1450 primary meter support 1.3.1.29401 - Bug fixed: Power Curves did not show all the data points 1.3.1.29248 - Added support for Reactor Switch controlling Voltage 1.3.1.29059 - Bug fixed: Power Curves screen issues 1.3.1.28694 - Bug fixed: For some locales the heat trends showed bad data (scaled wrong) - Changed the naming for phase rotation to ACB and ABC instead of Positive and Negative 1.3.1.28547 - Bug fixed: Phase balance filter uses Furnace RatedMVA to work with small furnaces 1.3.1.28304 - Bug fixed: Furnace Overview - The PigIronweight was added twice in the display of TotalWeight - Bug fixed: The Vibration event was being displaied as tent - Bug fixed: Event log viewer threw an exception when changeing chart types 1.3.1.27856 - Bug fixed: HMI Power Curves Screen error at selecting the charts. 1.3.1.27603 - Bug fixed: HMI Download from server was missing some files. - Bug fixed: Furnace taps uses the last available tap information when inserting new taps 1.3.1.27397 - Bug fixed: In external data, the load of the statistics grid now loads its content. - Bug fixed: In external data chart, the variables are selected corrctly now and search works in as expected. 1.3.1.26951 - Created DiagnosticsDB2 web page to query events in different days. The page has two calendars for start and end date, the query is performed in each day of the period and the results are added together chronologically, the sort order of the query if specified is not applied to the multi-day result set. Power Curves: Bug fixing and new features - Bug fixed: CreateSamplesSeries method was previously commented causing non series initialization. - Bug fixed: PowercurveDataView close button event was not handled. - New feedback icon at the status bar with valuable information when a Electrical System or Furnace Type models are incomplete or had invalid values. ShortCircuit Report - New feedback icon with valuable information when a Electrical System or Furnace Type models are incomplete or had invalid values. 1.3.1.26846 - New Online Help based on a Single Web Page. SQLite-based Online help files deleted. 1.3.1.26819 - Fixed Power On Column at Heat Sheet - Events - Fixed a potential incorrect message at temperature samples in overview screen. 1.3.1.26059 - Improvements in PhaseBalance Screens. - Added Balance column in statistics grid - Blur option for XYColor charts - Fixed a potential model corruption in the model Undo button - Fixed External Data loading issues - Fixed miscellaneous Event Log Viewer issues 1.3.1.25751 - Fixed a problem that prevented the save of the PhaseBalance Calculations - Fixed a problem in the calculation of the non filtered registries in phase balance 1.3.1.25735 - Fixed a problem that prevented the creation of the Phase Balance repository 1.3.1.25710 - Fixed the process that collects the data packages from the electrode speed tests - Added Electrode Speed Tests categories at load dialog. They are now separated into successful and failed / aborted. - Fixed the export of the Phase Balance Data 1.3.1.25640 - Fixed a potencial corruption problem with models 1.3.1.25599 - Fixed problem with heat sheet database that invalidated the TimeLine. 1.3.1.25441 - Fixed format of data exported from Electrode tests to include milliseconds - Increased capacity of heat series to 60000 (up to 6 years of heats) - Changed web service timeout of Event Log charts to 10 min - Fixed problem with heat sheet trends chart to update only if date range changed - Fixed arrangement of heat sheets for multi-year queries - Fixed problem when opening CSV files (event export file) to show the appropiate Variable Selector - Fixed problem with variable filtering - Fixed problem to avoid opening a heat chart of the wrong heat - Fixed problem with timeline when connecting to old web servers - Fixed problem where log Processor main thead was not calling BalanceProcessor. BalanceProcessor added to calling processors list. - Set PlatformTarget to x86 in order to avoid problems loading (shipped SQLite.DLL that is x86) in x64 operative systems. 1.3.1.25050 - Bug fix. NCC Setpoint display – value was divied by 10 when decimals configuration is zero. - Bug fix. Balance Screen – Reset button throw an exception. 1.3.1.25036 - Timeline screen fixes. 1.3.1.24747 - Latest temperature samples panel at the Overview screen. - Temperature, C, Ppm columns added to events grid at the Performance Heat Sheet screen. 1.3-1.24105 - New User Defined Variables screen in Comm Setup - Minor bugs fixed - Regulator Profile screen: item size - Histogram chart: X scale - DataHandling: Keep state of selected variables for each chart type. - Configuration Cache win service: Connection problem might cause problems with HmiServer module on regulator. 1.3-1.23797 - Limits the timeout time and number of tries in Trends and ConfigurationCache services - Bug fixed. LogPackageExists - WebClientCache expiration time reduced. - Fixed: app_offline.htm removed ........ - Balance Screen and Processor - Model Modification Timestamp transform To local Time for display. - Bug fixed: DateTime kind property added in order to make rigth convertion to localtime for display and tooltip. - Bug fixed: VMEIO Channel swaping at model edition on HMI - Minor fixes in map. 1.3-1.23127 - Bug fixed: Removed last-10-tests restriction on Electrode Test selection screen. It will allow display of up to 1000 tests. BugzID: 2979 1.3-1.22985 - Avg curve removal fail when same or other variable with the same name has been added. - PreemptiveCaveIn status, count and time available in event logs - Shaper Preemptive CaveIn can disable use of FastRaise valve - VmeIOConfiguration model validated when model's timestamp changed, it always happened when user open the screen or any other user make a change and save the model. - Validation added to VmeIOConfiguration model before save - check for duplicate channel name or number or if a "built-In" channel name is not present. - Async heat browsing support. - If Twin shell, navigate only through selected shell. - Fixed a problem in event log charts, the user could add but not remove Average pencils 1.3-1.22761 - OvercurrentTimeToTrip support added. - Bug fixed: Fixed heat navigation in Scatter charts. - Bug fixed: Avoid exception thrown by an edition in a deleted DataLine. - Fixed documentation for ExternalPresseure in input map 1.3-1.22692 - Bug fixed: Fixed memory problem in the Heat Sheet Report screen. 1.3-1.22528 - Bug fixed: Scatter chart display correction when switching variables and moving between heats / time - Bug fixed: Exported from heat chart was corrupt - Bug fixed: Heat timeline built from heatsheets table - Wrong Regulator - Heat Sheet Report display caused by a wrong merge fixed - Fixed unhandled exception in Source Impedance processing 1.3-1.22202 - Fixed unhandled exception in Source Impedance processing BugzID: 2958 - Added HeatSheet display for ShadowMode as Other, including the percent of time it was running in Shadow mode BugzID: 2957 - Added HeatSheet.ShadowModePwrOnPercent, percentage of time that the PX3 ran in Shadow mode Removed spurious Bounce fields BugzID: 2957 1.3-1.22161 - Bug fixed: Fixed unhandled exception in Source Impedance processing - Added HeatSheet.ShadowModePwrOnPercent, percentage of time that the PX3 ran in Shadow mode Removed spurious Bounce fields - Added HeatSheet display for ShadowMode as Other, including the percent of time it was running in Shadow mode - Added HeatSheet.ShadowModePwrOnPercent, percentage of time that the PX3 ran in Shadow mode - Removed spurious Bounce fields 1.3-1.22154 - Bug fixed: Twin Shell fixes and features. 1.3-1.21927 - Bug fixed: Spell error at "Substation" string. Prevents an unhandled exception in the Substation tab within the Electrical System section. 1.3-1.19340 - Bug fixed: Number of taps, backward support. - Bug fixed: Memory usage improved. Series allocation will be size fixed to retrived data size. - Bug fixed: ExternalLoopDisabled alarm restored - Bug fixed: Dynamic NCC setpoint rescaled dynamically - Bug fixed: VmeIOConfiguration model requested at data binging - Bug fixed: IndexOutOfRangeException fixed. - Bug fixed: Dynamic NCC setpoint rescaled dynamically - Bug fixed: ScaleFactor calculation for wide format display - Bit renamed to Operation.ShadowMode (inputs updated) Display "Other" when a bit for Shadow Mode. Bit renamed to Operation.ShadowMode - /Lb/Lc & Mab,Mbc,Mca hidden from user. - Bug fixed: Wrong handling of the new property "NumberOfTaps". backward compatibility - Plot calculation adjusments, visual adjusments - Feature: New Discretize Color axis, CustomZedGraph now setup discretize x,y and z series. - Bug fixed: ZedGraph Line and Symbol preferences editors. - Bug fixed: Miss columns added to HeatSheets table - Reload button added to grid views (Modification History) - Custom Series data added to export file. - GroupingGridControl by Syncfusion implemented in Modification History screen - Feature: Let move a variable to a particular group (category). I2TMwh moved to Electrical - Bug fixed: Link button in Performance Heat Sheet was pointing to old Power Curves screen. * Shadow Mode variable in map added to help. * Code Clean up - Bug fixed: Default sort orientation (ASC) for versions list (Modification History) - Tool tips added - Bug fixed: Disposing controls referenced in a dictionary member. - Bug fixed: Validation to avoid navegate after current heat number - Bug Fixed: Disposing controls to avoid memory and user object leaks - Bug fixed: because a bad Chart model clearence inside EventLogViewer inasmuch as it is received by reference in the constructor caller class should manage the this IChartModel instance. - Added help message to RphToCsv tool BugzID: 2798 - Bug fixed: OutOfMemoryException handling. ModelManager will try to allocate the Serie (array of doubles) if it fails then will close prevous oppened screens in order to release memory. A memory wastage fixed in PowerCurves screen, when allocating char... - Bug fixed: The csv columns names are translated into an internal name Object_Variable in order that all variables be found. - Bug fixed: VmeIOConfiguration model requested at data binging - Minor layout imporvements - XYColor scaling removed from scale selector. - Bug fixed: at XYColor scale (auto). - Bug fixed: Wrong call to CreateEventRulers when in a XYColor chart. - Bug fixed: Resolving expresion variable paths. - Bug fixed: Cross-thread bug between data update and paint calls, fixed. - Bug fixed: ExternalLoopDisabled alarm restored - Bug fixed: Exception handling in input_PreviewInputValueUI - Bug fixed trying to delete custom variables - Bug fixed: Filtering non-exportable variables (columns in BD), Changing Contains("id") to Equals("id") - Bug fixed: Manually load KernelMessage Table with DataReader. Force default Decimal columns to Double C# types for safety reasons. Bug fixed: DbNull handling - Bug fixed: Event Browser - Heat Number display when heat number is only one digit. - Bug fixed: EventLogViewer initial state - Selection and Averages 3ph var definition problem - Bug fixed: EventLogViewer unhandled exception - SingPh transients. Fixed. - Bug fixed: EventLogViewer grouping - DEBUG messages. It was a race condition when recreating series. - Bug fixed: Transient Variable Selector initial state bug fixed. - Bug fixed: Event Browse selection ignored the first time bug fixed. - Documentation fixed: External Loop Disabled bit is now included - Documentation fixed: SmartARCInputs BalanceSP uses two decimals